Condensate Drain

Timer-Controlled Automatic Condensate Drain Valve | Brass Solenoid

Economical timer-controlled brass solenoid condensate drain valves with adjustable pulse and pause intervals for air receivers and filters — HAVKOM.

Our Service & Engineering Scope

Turnkey supply, calibrated engineering tests, and certified independent technical service for maximum plant uptime.

  • Air receiver and distribution drop leg timed drain valve fitting
  • Pulse duration and pause interval seasonal calibration
  • Integrated ball valve strainer screen removal and cleanout
  • Solenoid coil electrical continuity and plunger armature inspection
  • Manual push-to-test cycling and seat seal leak verification
Timer-Controlled Automatic Condensate Drain Valve | Brass Solenoid
HAVKOM Mühendislik

Technical Specifications & Parameters

Key operating metrics, operational thresholds, and quality benchmarks engineered for uninterrupted industrial duty.

Valve ConstructionHeavy Forged Brass Direct-Acting Solenoid Valve
Interval CalibrationDischarge: 0.5–10 sec | Pause Interval: 0.5–45 min
Strainer ProtectionIntegrated Stainless Mesh Ball Valve Strainer
Working Pressure0 – 16 bar (g)
Manual TestPush-to-Test Manual Cycling Button & LED Indicators
Protection RatingIP65 Moisture & Dust Tight DIN 43650A Connector

Engineering Principles & Working Mechanism

Timer-controlled automatic condensate drain valves combine a rugged forged brass direct-acting solenoid valve with an integrated dual-potentiometer analog timer module, providing an economical and dependable liquid drainage solution.

Two rotary potentiometers allow operators to independently calibrate discharge pulse duration (0.5 to 10 seconds) and interval pause timing (0.5 to 45 minutes) based on ambient humidity. An integrated stainless mesh strainer protects the solenoid valve seat from welding slag and pipe debris.

At HAVKOM Engineering, we supply 230V AC and 24V DC heavy-duty timed drain valves complete with ball valve strainers, test buttons, and IP65 protection ratings.

HAVKOM Independent Engineering Assurance

Seeking a rugged, economical, and field-adjustable drain valve for receiver tanks and aggressive factory environments? Our engineering team tunes interval and discharge timing to automate water evacuation without draining line pressure.

In-depth Technical Guide

Air Receiver Tank Condensation & Solenoid Drain Troubleshooting

Read Article

Frequently Asked Questions

Should timer drain valve settings be adjusted between seasons?

Yes. Hot humid summer air causes compressors to generate 3 to 4 times more condensate than winter. Interval pause timing should be reduced in summer (e.g., every 8–10 minutes) to avoid reservoir flooding.

What causes the timed solenoid valve to hiss and leak air continuously?

Fine pipe scale or rust particles lodge beneath the rubber valve seat, preventing complete shutoff. Cleaning the integrated ball valve mesh strainer usually remedies the issue.

Contact our engineering team for proper product sizing and quote request.